maintenance
Warning
Non professionals are not allowed to perform maintenance operations.
Regular maintenance according to the user manual is essential for the normal operation and extended service life of the tire dismantling machine.
If the machine is not regularly maintained, its operation and reliability cannot be guaranteed, and both the operator and people near the machine are at risk.
Before carrying out any maintenance operations, defective components that have been disconnected from the power supply must be replaced by professionals using original spare parts provided by the manufacturer. Special note: The manufacturer shall not be held responsible for complaints arising from the use of spare parts produced by other manufacturers, or for losses caused by the removal or damage of safety devices.
Without permission, it is not allowed to modify the components on the equipment.
Attention: Keep the workplace tidy.
calibration
1.100g calibration
When the device experiences inaccurate measurements, please recalibrate the device to 100g.
1. Install a wheel that can clamp lead blocks, enter the data of the wheel rim (A, B, D values), press the C key to enter the system menu, the digital display shows "CAL CAL", press the START key to enter calibration mode.

2. Press the START button to start the balancing machine. After the wheels stop, manually rotate the wheels to turn on the outer unbalanced position indicator lights. Place a 100g lead block at the 12 o'clock position on the outer side of the wheels.

3. Press the START button to start the balancing machine. After the wheels stop, remove the 100g lead block on the outer side of the wheel, manually rotate the wheel to turn on all the unbalanced position indicator lights on the inner side, and place the 100g lead block at the 12 o'clock position on the inner side of the wheel.

4. Press the START button to start the balancing machine. After the wheels stop, the calibration is complete and the unbalance of the wheels at the last rotation is displayed.
Calibration of 2 rulers
When the size measurement of the device is inaccurate, the ruler can be recalibrated.
1. Install a wheel on the balancing machine. Press the C key to enter the system menu, press the R key to switch menu options, the digital display shows "ruler", press the START key to enter the ruler calibration function, the left digital display shows "d16", and the right digital display shows the data sampled by the ruler.
2. The left digital display shows "d16". Press the D+or D - keys to change the value of d to the diameter of the installed wheel. Pull out and rotate the ruler to the measurement position of the wheel diameter, and press the START key to confirm.

3. The left digital display shows "-15". At this point, pull out the ruler by 15cm, press the START button to confirm, and the digital display shows "End". The ruler calibration is complete. Press any key to exit.
3-wheel width gauge calibration (optional)
Calibrating the external measuring ruler is the third item in the settings menu, "b-cal" (be sure to calibrate the automatic ruler before calibrating the wheel width ruler). Press the START button to enter the calibration of the external measuring ruler.
If equipped with a mechanical external measuring scale, the calibration steps are as follows:
1. Place the rod of the external measuring ruler on the screw shaft (when the rod rotates towards one side of the box, the sampling value should increase), and press the START button to confirm.

2. Install a wheel, press the b+or b - key to enter the width value for calibrating the wheel, place the measuring tape and outer measuring tape at the measurement position for about 2 seconds, and then calibrate. Press the START key to return.
If equipped with a sonar external measuring scale, the calibration steps are as follows:
After entering the external measuring scale calibration, the digital display shows "a ---". Install a wheel and use a ruler to measure the A and D values of the wheel. After the measurement is completed, proceed directly to the next step.
2. Press the up or down key to enter the B value of the wheel, lower the protective cover, and the digital display on the right will show the value measured by the ultrasonic sensor.
3. Press the START button to complete the calibration.
4 System parameter settings
Press the C key to enter the system menu, press the R key to switch menu options, the digital display shows "SETUP", press the START key
Enter the system settings menu.
1. Unbalanced weight hiding: Press the A+or A - keys to modify, with options of 05, 10, and 15. Press R to save and enter the next item, and press the START key to save and exit.

2. Operation sound reminder: Press the A+or A - key to modify, with options of ON and OFF. Press R to save and enter the next item, and press the START key to save and exit.

3. Display brightness adjustment: Press the A+or A - key to modify, with options ranging from 1 to 6 levels. Press R to save and enter the next item, and press the START key to save and exit.

4. Wheel cover control switch: Press the A+or A - key to modify, with options of ON and OFF. Press the R or START key to save and exit.

5.Laser indicator switch: Press the A+or A - key to modify, with options of ON and OFF. When set to "ON", the Laser indicator light will light up. Press the R or START key to save and exit

6. Extended ruler switch: Press the A+or A - key to modify, with options of ON and OFF. Press the R or START key to save and exit.

7. Wheel width ruler setting switch (only available when a mechanical wheel width ruler is selected): Press the A+or A - key to modify, with options of ON and OFF. If a wheel width ruler is installed, set it to ON; otherwise, set it to OFF. Press the R or START key to save and exit.

8. Language setting: Set the language of the voice prompt (optional), press the A+or A - key to modify, options include EN (English), Cn (Chinese), press R to save and enter the next item, press START key to save and exit.

9. Voice prompt (optional) switch: Press the A+or A - key to modify, with options of 0, 1, and 2. When set to 0, the voice prompt is turned off. When set to 1, the voice prompt is only used for various calibrations. When set to 2, the voice prompt is fully turned on, and all operations are prompted. Press R to save and enter the next item, press START to save and exit.

Attention: Voice prompt is an optional feature. If the device is not equipped with voice prompt function, set this option to 0. Equipment detection
Press the C key to enter the system menu, press the R key to switch menu options, the digital display shows "CHECK", press the START key to enter
Detection function
1. Display test and sound test, press the R key for the next item, press the STOP key to exit.

2. Pull the ruler angle sensor for detection. Rotate the ruler by hand, and if there is a change in the value on the right side, it is considered normal. Press the R key for the next item, and press the STOP key to exit.

3. Use the length sensor to detect the length of the ruler. Pull out the ruler by hand, and if there is a change in the value on the right side, it is considered normal. Press the R key to enter the next item, and press the STOP key to exit.

4. Piezoelectric sensor detection: Press the balance shaft with your hand, and if there is a change in the values on both sides, it is considered normal. Press the R key to enter the next item, and press the STOP key to exit.

5. Light partition detection, manually rotate the wheel to change the value to normal, press the R key to enter the next item, and press the STOP key to exit.

Attention
The above table and information on firefighting materials are only provided for basic guidance to users. Specific details should be contacted with professional firefighting agencies
troubleshooting
All issues must be inspected and resolved by professional personnel. If there are no professionals, it is necessary to contact the dealer to obtain relevant technical services to avoid wasting time.